Table 8-5 Parameters for oscillation inhibition
Numeric
Display
Variable Name
Meaning
Default
Value
Ran
ge
d2.03
Notch_N
Notch/filtering frequency setting for a velocity
loop, used to set the frequency of the internal
notch filter, so as to eliminate the mechanical
resonance produced when the motor drives
the machine. The formula is F = Notch_N*10 +
100.
For example, if the mechanical resonance
frequency is F = 500 Hz, the parameter should
be set to 40.
45
0~9
0
d2.04
Notch_On
Enable or disable the notch filter
0: Disable the notch filter
1: Enable the notch filter
0
/