Calculate
according to the required dead zone voltage:
8191
2_ *
10
dead
Analog Dead U
v
Result:
= 410
Calculate
according to the required offset voltage:
8191
2_ *
10
shift
Analog Offset U
v
Result:
=819
The following changes are required on the basis of Example 7-7.
Table 7-19 Parameter settings in Example 7-8
Sets dead zone data for
external analog signal 2
Sets offset data for
external analog signal 2
Sets the proportion
between analog signals
and output torque
(current)
1: Storing all configured
parameters for the
control loop
10: Initializing all
parameters for the
control loop
7.4 Internal Multi-position Control Modes (“1” Mode)
In Internal multi-position control mode, we can activate internal set target position though an external signal to
control motors. The activation has two preconditions:
1, multi-position control mode can only be activated in Mode 1, it can’t be activated in other modes.
2, At least one of the external input signal is defined as “Internal position control 0”, “Internal position control 1
“ or “Internal position control 2 “, which means at least one address of digital tubes-d3.01 ~ d3.07 is set to
“040.0”’, “080.0” or “800.2.
“Internal position control 0” , “Internal position control 1” and “Internal position control 2 “, these three
signals will be combined into binary codes used to select a target position between “Position 0~7”.
Position section
numberic display