43
OPTIONAL ACCESSORIES
Cleaning sealed Hard Floors
The Shampoo Tank with additional liquid is used when cleaning
sealed hard floors such as vinyl or tile.
1
Fill the Shampoo Tank at the sink. Unscrew the large cap
from the top of the Shampoo Tank. Turn the Suds Control
Valve to OFF. Fill the tank to the first line with water.
Using the large cap from the top of the tank, pour one
capful of Kirby® Hard Floor Cleaner into the Shampoo
Tank. Do not use more, as over-foaming will result.
Replace the large cap on the Shampoo Tank.
Use only Kirby® cleaning solutions, such as Kirby Hard
Floor Cleaner Concentrate, intended for use with this
product. Failure to follow this warning could result in
injury due to internal component damage.
2
Firmly connect the elbow hose to the Multi-Surface
Shampoo Nozzle.
3
Taking care to avoid spilling liquid on the unit or the floor,
place the opening in the bottom of the Shampoo Tank over
the Air Exhaust Port.
Rotate the Shampoo Tank toward the unit to lock it in place.
4
Connect the elbow hose to the bottom of the Shampoo Tank.
5
Press the Toe-Touch Control Upper Pedal repeatedly until the
Rotary Mop contacts the floor.