DP770 Service Manual
SQL1 Open
instrument to RX mode
2
)Set RF Gen Freq to test
frequency
3)
S
et Amplitude t
o
-123d
Bm1(25KHz)or -121dBm
(12.5KHz)
4)
S
et AFGen1 Freq to 1kHz
5)
S
et FM to 3kHz(25KHz)
or
HP8921A or
similar
instrument
Connect the
antenna port to
RF IN/OUT port
of instrument by
antenna
connector
adapter
PC
1. Enter tune mode
2. Double click”SQL1 Open”and enter to F
1
t
o F8 to adjust different frequency
3. Click “Start”.
4. Click “Stop” when the value is stable.
5. Click save
Open:-119dBm
Close -127dBm
SQL1 Close
instrument to RX mode
2
)Set RF Gen Freq to test
frequency
3)
S
et Amplitude t
o
-125d
Bm(25KHz)or -123dBm
(12.5KHz)
4)
S
et AFGen1 Freq to 1kHz
5)
S
et FM to 3kHz(25KHz)
or
1.Enter tune mode
2.
D
ouble click”SQL1 Open”and enter to F1 t
o
F
8 to adjust different frequency
3. Click “Start”.
4. Click “Stop” when the value is stable.
5. Click save
SQL9 Open
instrument to RX mode
2
)Set RF Gen Freq to test
frequency
3)
S
et Amplitude to -116dBm
4)
S
et AFGen1 Freq to 1kHz
5) Set FM to 3kHz(25KHz)
or
1.Enter tune mode
2.
D
ouble click”SQL9 Open”and enter to F1 t
o
F
8 to adjust different frequency
3
. C
lick “Start”.
4.
C
lick “Stop” when the value is stable.
5.Click save
Open:-115dBm
Close -120dBm
SQL9 Close
instrument to RX mode
2
)Set RF Gen Freq to test
frequency
3)
S
et Amplitude to -119dBm
4)
S
et AFGen1 Freq to 1kHz
5)
S
et FM to 3kHz(25KHz)
or
1.Enter tune mode
2.Double click”SQL9 Close”and enter to F1 to
F8 to adjust different frequency
3
. C
lick “Start”.
4. Click “Stop” when the value is stable.
5.Click save
Page 29 of 102