2-4 CHAPTER 2 Specifications
Series 5000 V2 Sonar System Operations and Maintenance Manual P/N 11214512, Rev. 04
2.3.5 A/D Converter
Type: Pipeline
Resolution: 14 bits
Quantization: Linear
Sample rate: Proprietary
2.3.6 Multiplexer
Modulation format: Pulse code modulation (PCM)
Multiplexing format: Time division multiplexing (TDM)
Number of channels: 32
Data rate: 29.12 Mbaud
Data format: NRZ
Bit error rate: Better than 1x10
-8
(before correction)
2.3.7 Power
Input power: Powered from the TPU; no additional
power required
2.3.8 Heading Sensor
Accuracy level: ±0.5 RMS
Accuracy tilted: ±1.0 RMS
Resolution: 0.1
Repeatability: ±0.1
2.3.9 Pitch and Roll Sensor
Accuracy: ±0.2 RMS
Resolution: 0.1
Repeatability: ±0.2
2.3.10 Pressure Sensor
Pressure range: 0–750 psig
Accuracy: ±0.10%