4 Trouble-shooting
In the event of malfunctions which the power source itself recognises, in the display field an "E" followed by a
number will be shown. The following table shows the type of error.
4.1 Error Signals from the Power Source
Mains power supply too high or too low
Ensure correct mains power supply
Interruption of discharge resistance
Change discharge resistance
Ensure better cooling, allow equipment
to cool down while idling.
Capacitors, diode D1 or charging
source defective
Short circuit of lifting solenoid or
control cable
Short circuit MOSFET discharge circuit
MOSFET discharge circuit does not switch
Issue 4/2019 ver. 2.0 page 21 of 42
Köster & Co. GmbH • D-58256 Ennepetal • Spreeler Weg 32 • Tel. +49 2333 8306-0 • Fax +49 2333 8306-38