EasyManua.ls Logo

Kohler 10CCOZ61

Kohler 10CCOZ61
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-12 Scheduled Maintenance TP-5648 8/93
Servicing Cooling System
For servicing the 10CCOZ generator set, refer to
Figure 3-10 for proper coolant system disassembly and
reassembly sequence. During the reassembly
procedure, follow the General Torque Specifications
found in Section 10. This generator set features a
blower-type fan mounted to the hub, which is mounted
to the crankshaft pulley. The blower fan draws air over
the generator set and blows it through the radiator to
cool the engine. See Figure 3-11.
Check and maintain the coolant level at the coolant
recovery tank. See Figure 3-12 for tank location and
Figure 3-13 for coolant capacities.
Observe the following recommendations for properly
maintaining the generator sets coolant system:
D Never use dirty water or sea water as coolant.
D Always use a 50% mixture of clean water and
antifreeze for coolant.
D Make sure the pressure cap is tightened after
using.
D Do not fill the coolant beyond the HOT mark on
the coolant recovery tank.
Refer to Figure 3-14 for remote radiator specifications.

Table of Contents

Related product manuals