EasyManuals Logo

Kohler KD62V12 Operation And Maintenance Manual

Kohler KD62V12
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
Maintenance
Lubricants and operating fluids
Biodiesels
Only diesel fuels with a biodiesel content lower than 10% are allowed in Kohler KD diesel
engines.
Information
Diesel fuels with a biodiesel content between 10% and 20% may be used, but Kohler do not
recommend it as the operating costs linked to maintenance will drastically increase.
Fuel standard
(norm)
Fuel quality
(norm complement)
Required
lubri‐
cating
capacity
(max.
HFRR)
Required
max.
biodiesel
ratio (%)
Additional required
criteria
Compat‐
ible with
EATS
Perform‐
ance alter
ation /
Reduced
mainte‐
nance
interval
EN 14214 - - 10% Fuel storage
Fuel filtration
No
Yes
5) 6) 7) 8)
9)
EN 14214 - - 20% Fuel storage
Fuel filtration
No
Yes
5) 6) 7) 8)
9)
ASTM D6751 - - 10% Fuel storage
Fuel filtration
No
Yes
5) 6) 7) 8)
9)
ASTM D6751 - - 20% Fuel storage
Fuel filtration
No
Yes
5) 6) 7) 8)
9)
Tab. 27: KD approved biodiesel fuels
Paraffinic fuels (according to EN 15940)
Paraffinic fuels (“synthetic diesel”) have a high cetane number and a low density compared to
diesel fuels. HVOs (Hydrotreated Vegetable Oils) are renewable. GTLs (Gas-To-Liquids) are fossil
paraffinic fuels. The use of paraffinic fuels results in lower emissions, but also slightly higher
fuel consumption and lower performance.
When using paraffinic diesel, a reduced filter change interval may be necessary due to the
cleaning effect.
Rubber and elastomers in the fuel system can be affected when changing from diesel fuel to
paraffinic fuel. Check daily whether fuel is leaking, and contact customer service for assistance
if necessary.
Information
EN 15940 fits into specification ASTM D975 1D-15 and ASTM D975 2D-15.
5)
Exchange interval of fuel filters is reduced (1/2), lifespan of fuel line components may be
reduced, fuel consumption is not guaranteed anymore.
6)
Biodiesels are not recommended for ESP (Emergency Standby Power) generator set applica‐
tions because of the risk of bacteria development.
7)
Specific improved storage condition is mandatory.
8)
Reinforced fuel primary filtration system, including water separator between main storage
and daily tank, is mandatory.
9)
Polishing primary fuel filtration is mandatory.
KD62V12 33521030301_8_1 EN_US 2022-09
© 2022 by Kohler Co. All rights reserved.
145

Table of Contents

Other manuals for Kohler KD62V12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD62V12 and is the answer not in the manual?

Kohler KD62V12 Specifications

General IconGeneral
BrandKohler
ModelKD62V12
CategoryEngine
LanguageEnglish

Related product manuals