Error code
SPN FMI Designation
516123 11 Common rail - Start pressure too low
1349 0 Common rail 2 - Critical overpressure
1240 2 Common rail 2 - Leakage
1349 15 Common rail 2 - Overpressure warning
516124 11 Common rail 2 - PCV opened due to overpressure
516125 11 Common rail 2 - Plausibility error of VCV current
516128 11 Common rail 2 - Pressure remains above the set point
516129 11 Common rail 2 - Pressure remains below the set point
516130 11 Common rail 2 - Start pressure too low
1239 0 Common rail leakage 1 - Fuel leak
1239 11 Common rail leakage 1 - Out of range
1239 31 Common rail leakage 1 - Supply voltage out of range
1240 0 Common rail leakage 2 - Fuel leak
1240 11 Common rail leakage 2 - Out of range
1240 31 Common rail leakage 2 - Supply voltage out of range
516131 11 Common rail pressure sensor - No signal variation
157 3 Common rail pressure sensor - Short circuit to battery or open
circuit
157 4 Common rail pressure sensor - Short circuit to ground
157 31 Common rail pressure sensor - Supply voltage out of range
516133 11 Common rail pressure sensor 2 - No signal variation
1349 3 Common rail pressure sensor 2 - Short circuit to battery or
open circuit
1349 4 Common rail pressure sensor 2 - Short circuit to ground
1349 31 Common rail pressure sensor 2 - Supply voltage out of range
2430 11 Coolant level sensor - Out of range
2430 3 Coolant level sensor - Short circuit to battery
2430 4 Coolant level sensor - Short circuit to ground or open circuit
2430 31 Coolant level sensor - Supply voltage out of range
6303 11 Coolant level sensor 2 - Out of range
6303 3 Coolant level sensor 2 - Short circuit to battery
6303 4 Coolant level sensor 2 - Short circuit to ground or open circuit
6303 31 Coolant level sensor 2 - Supply voltage out of range
6209 0 Coolant temperature at intercooler - Critical overtemperature
6209 15 Coolant temperature at intercooler - Overtemperature warning
110 5 Coolant temperature sensor - Open circuit
110 3 Coolant temperature sensor - Short circuit to battery
110 4 Coolant temperature sensor - Short circuit to ground
172
© 2022 by Kohler Co. All rights reserved.
KD62V12 33521030301_8_1 EN_US 2022-09

Table of Contents

Other manuals for Kohler KD62V12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD62V12 and is the answer not in the manual?

Kohler KD62V12 Specifications

General IconGeneral
BrandKohler
ModelKD62V12
CategoryEngine
LanguageEnglish

Related product manuals