Appendix
Error code
SPN FMI Designation
659 0 Injector 9 - Current Rise time too long
659 8 Injector 9 - No current rise time measured
659 5 Injector 9 - Open cirscuit
659 3 Injector 9 - Short circuit to battery
659 4 Injector 9 - Short circuit to ground
516191 17 Injector supply boost converter - Undervoltage warning
105 5 Intake air temperature sensor - Open circuit
105 3 Intake air temperature sensor - Short circuit to battery
105 4 Intake air temperature sensor - Short circuit to ground
105 31 Intake air temperature sensor - Supply voltage out of range
102 0 Intake manifold - Critical overpressure
1636 0 Intake manifold - Critical overtemperature
102 1 Intake manifold - Critical underpressure
102 15 Intake manifold - Overpressure warning
1636 15 Intake manifold - Overtemperature warning
102 17 Intake manifold - Underpressure warning
102 3 Intake manifold pressure sensor - Short circuit to battery
102 4 Intake manifold pressure sensor - Short circuit to ground or
open circuit
102 31 Intake manifold pressure sensor - Supply voltage out of range
1636 5 Intake manifold temperature sensor - Open circuit
1636 3 Intake manifold temperature sensor - Short circuit to battery
1636 4 Intake manifold temperature sensor - Short circuit to ground
1636 31 Intake manifold temperature sensor - Supply voltage out of
range
6209 5 Intercooler coolant temperature sensor - Open circuit
6209 3 Intercooler coolant temperature sensor - Short circuit to
battery
6209 4 Intercooler coolant temperature sensor - Short circuit to
ground
6209 31 Intercooler coolant temperature sensor - Supply voltage out of
range
516197 2 Master slave injection - Communication error
516223 11 Monitoring system - Engine control unit internal safety error
516226 11 Monitoring system - Injector safety error
100 3 Oil pressure sensor - Short circuit to battery
100 4 Oil pressure sensor - Short circuit to ground or open circuit
100 31 Oil pressure sensor - Supply voltage out of range
175 5 Oil temperature sensor - Open circuit