Appendix
Error code
SPN FMI Designation
175 3 Oil temperature sensor - Short circuit to battery
175 4 Oil temperature sensor - Short circuit to ground
175 4 Oil temperature sensor - Short circuit to ground or open circuit
175 31 Oil temperature sensor - Supply voltage out of range
4811 0 Piston cooling pressure 1 - Critical overpressure
4811 1 Piston cooling pressure 1 - Critical underpressure
4811 15 Piston cooling pressure 1 - Overpressure warning
4811 17 Piston cooling pressure 1 - Underpressure warning
4811 3 Piston cooling pressure sensor 1 - Short circuit to battery
4811 4 Piston cooling pressure sensor 1 - Short circuit to ground or
open circuit
4811 31 Piston cooling pressure sensor 1 - Supply voltage out of range
3597 1 Power supply - Critical undervoltage
3597 15 Power supply - Overvoltage warning
3597 17 Power supply - Undervoltage warning
5571 6 Pressure control valve - Critical high output current
5571 0 Pressure control valve - Critical overcurrent
5571 1 Pressure control valve - Critical undercurrent
516209 15 Pressure control valve - Current remains above the set point
516209 17 Pressure control valve - Current remains below the set point
5571 11 Pressure control valve - Electrical error
5571 5 Pressure control valve - Open circuit
516211 11 Pressure control valve - PWM signal - High limit reached
516212 11 Pressure control valve - PWM signal - Plausibility error
516422 11 Pressure control valve - Short circuit load
5571 3 Pressure control valve - Short circuit to battery high side
516331 3 Pressure control valve - Short circuit to battery low side
5571 4 Pressure control valve - Short circuit to ground high side
516331 4 Pressure control valve - Short circuit to ground low side
516215 6 Pressure control valve 2 - Critical high output current
516215 0 Pressure control valve 2 - Critical overcurrent
516215 1 Pressure control valve 2 - Critical undercurrent
516216 11 Pressure control valve 2 - Current remains above the set point
516217 11 Pressure control valve 2 - Current remains below the set point
516337 11 Pressure control valve 2 - Electrical error
516215 5 Pressure control valve 2 - Open circuit
516220 11 Pressure control valve 2 - PWM signal - High limit reached
516221 11 Pressure control valve 2 - PWM signal - Plausibility error
KD62V12 33521030301_8_1 EN_US 2022-09