INFORMATION ABOUT MAINTENANCE
5
37
EN
Internal Communication: For internal & partner use only.
5.15 Engine starting after storage
1. Remove the protective sheet.
2. Use a cloth soaked in degreasing product to remove the protective treatment from the external
parts.
3. Inject lubricating oil (no more than 2 cm
3
) into the intake ducts.
4. Refill the tank with fresh fuel.
5. Make sure that the oil and the coolant are up to the maximum level.
6. Start the engine and keep it idle at minimum speed for a two about minutes.
7. Bring the engine to 75% of maximum rated speed for 5 to 10 minutes.
8. Stop the engine while the oil is still hot (Par. 6.1), discharge the protective oil in a suitable container.
Warning
Over time, lubricants and filters lose their properties, so it is important consider whether they need
replacing, also based on the criteria described in Tab. 5.2.
9. Replace the filters (air, oil, fuel) with original spare parts.
10. Pour new oil (Par. 4.5) up to the maximum level.
11. Empty the cooling circuit completely and pour in the new coolant up to the maximum level (Par.
4.6).

Other manuals for Kohler KDI 2504TM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KDI 2504TM and is the answer not in the manual?

Kohler KDI 2504TM Specifications

General IconGeneral
BrandKohler
ModelKDI 2504TM
CategoryEngine
LanguageEnglish

Related product manuals