7
INFORMATION ABOUT FAILURES
EN 42
7 INFORMATION ABOUT FAILURES
7.1 Useful information about failures
This chapter contains information about the problems that may appear during engine operation with
its causes and trouble shooting Tab. 7.2.
In some cases, you shall turn off the engine immediately to avoid further damage Tab. 7.1.
Tab 7.1
THE ENGINE MUST BE IMMEDIATELY TURNED OFF WHEN
1
Warning RED light turn on
2
The oil pressure indicator light turns on while running
3
The engine rpms suddenly increase and decrease
4
A sudden and/or unusual noise is heard
5
Colour the exhaust fumes suddenly darkens
Tab 7.2
TROUBLES
POSSIBLE CAUSE
SOLUTION
PAR.
Warning YELLOW light
turn on
Engine ECU has detect a
malfunctions
Contact KOHLER authorised workshops
--
The engine does not
start
Sulphated battery
terminals corroded
Clean the battery terminals
--
Battery voltage too low
Recharge the battery or replace it
--
Low fuel level
Refuel
4.4
Frozen fuel
Contact KOHLER authorised workshops
--
Clogged fuel filter
Replace with a new filter
6.3
Air suction in fuel system
Contact KOHLER authorised workshops
--
Clogged air filter
Replace with a new filter
6.4
Clogged pipes
Contact KOHLER authorised workshops
--
Intake or exhaust system
clogged
Replace with a new fuse; if the problem
persists,
Contact KOHLER authorised workshops
--
Intake or exhaust system
clogged
Contact KOHLER authorised workshops
--
Engine starts but
stops
Inefficient electrical
connections
Clean the electrical contacts; if the problem
persists,
Contact KOHLER authorised workshops
--
Sulphated battery
terminals
Clean the battery terminals
--
Clogged fuel filter
Replace with a new filter and clean the tank
--
Clogged fuel pipes
Contact KOHLER authorised workshops
--
RPM instability at idle
speed
Clogged fuel pipes
Contact KOHLER authorised workshops
--
Numero dei giri al
minimo basso
Clogged fuel pipes
Contact KOHLER authorised workshops
--
Poor quality fuel
Clean the tank and refuel with quality fuel
2.5