SEN00791-02 40 Troubleshooting
Failure code [CA2352] EGR Valve Sol Current Low Error
Action code Failure code
Trouble
EGR Valve Sol Current Low Error
(Engine controller system)
E11 CA2352
Contents of
trouble
• Low current error occurred in drive circuit of EGR valve solenoid.
Action of
controller
• Limits output and continues operation.
• Close EGR and bypass valves.
Problem that
appears on
machine
• Engine output lowers.
Related
information
Possible causes
and standard
value in normal
state
Cause Standard value in normal state/Remarks on troubleshooting
Carry out troubleshooting for failure code [CA2351].