26.03.1996 • KHH SEENXL13A
For Authorized KCI Service Agents Only
KCI Hoists Corporation reserves the right to alter or amend the above information without notice
Page 26
XL
Service Manual
CU1
KCI KONECRANES GROUP
KCI HOISTS CORPORATION
2-393
2-3932-393
2-393 Option 3; DynAHoist option; Ready-output
Option 3; DynAHoist option; Ready-outputOption 3; DynAHoist option; Ready-output
Option 3; DynAHoist option; Ready-output (> P2.12)
Changes the operation of the Ready-output. This enables the Ready-output
to be connected to the DynAHoist's fault circuit (see Appendix 6).
2-413
2-4132-413
2-413 Option 4; Brake sensor (
Option 4; Brake sensor (Option 4; Brake sensor (
Option 4; Brake sensor (> P2.13)
P2.13) P2.13)
P2.13)
Changes the operation of the brake wear sensor input (see Appendix 6).
2-433
2-4332-433
2-433 Option 5; External overload alarm (
Option 5; External overload alarm (Option 5; External overload alarm (
Option 5; External overload alarm (> P2.13)
P2.13) P2.13)
P2.13)
An external overload alarm/warning can be controlled via CU1:7-8 (see
Appendix 6). Can not be used simuntaneously with Option 3.
2-425
2-4252-425
2-425 Option 6; External overtemperature and brake failure indicator
Option 6; External overtemperature and brake failure indicatorOption 6; External overtemperature and brake failure indicator
Option 6; External overtemperature and brake failure indicator
(
((
(> P2.13)
P2.13) P2.13)
P2.13)
An external overtemperature and brake wearing alarm/warning can be
controlled via CU1:7-8 (see Appendix 6). Can not be used simuntaneously
with Option 3.
2-000
2-0002-000
2-000 Shifts CU1 into the 3rd programming level
Shifts CU1 into the 3rd programming levelShifts CU1 into the 3rd programming level
Shifts CU1 into the 3rd programming level
Allows the use of password 3-511.
3-511
3-5113-511
3-511 Changing of supervisory and diagnostic values
Changing of supervisory and diagnostic valuesChanging of supervisory and diagnostic values
Changing of supervisory and diagnostic values
- SUP0 Reset all supervisory values
- SUP1 Set SWP (one can enter e.g. an old SWP-value from a replaced CU1)
- SUP2 Set Runtime
- SUP3 Set Starts
- SUP4 Set Overloads
- SUP5 Set SWP, Runtime, Starts and Overloads
- SUP6 Reset hoist use values: St-h, LSt-h, OH and brFC (see 1-
001)
- SUP9 Reset CU1's internal diagnostic values.
3-000 Exit
3-000 Exit3-000 Exit
3-000 Exit
Exits the programming and controlling mode (PAUSE-message displayed).
3-xxx Exit
3-xxx Exit3-xxx Exit
3-xxx Exit
Exits the programming and controlling mode (if a FAIL-message is
displayed, it can be ignored).

Table of Contents