22
454200/A
9Oncethedoorisstableinthetiltedposition,selectTilted.
10SelectSettoacceptthevalues.
Werecommendyoutowritedowntherelevantvaluesforeachdoor,incaseyou
needthemwhenyouchangedoorsorsensors.
11Disconnectthesensorfromtheinterfacecableandthecomputer.
Manuallyenteringtheknownpitchandroll
calibrationvaluesofasensoronthetrawl
door
Ifyouneedtoreplaceadoormountedsensor,youcanentertheknowncalibrationvalues
fromtheoldsensorbymeansoftheTV80withoutperforminganewcalibration.
Procedure
1ConnectthesensortoacomputerrunningtheTV80and/orPXCongurator
programswithadedicatedcable.
2Ontheprocessorunitdesktop,double-clicktherelevantprogramicontostartit.
3OpentheSetupmenu.
4OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.
5AtthebottomoftheSensorlistpage,selectAddNewSensor.
TheAddNewSensordialogboxopens.
6SelectY es.
7IntheveryrstPXSensorConguratordialogbox,selectcommunicationport
andsensortype,thenselectConnect.
TherelevantsensorConguratordialogboxopens.
8SelectCalibrateSensortoopenthedialogbox.
9EntertheknownvaluesinDoorInstallationOffsets.
IfyouareusingthecalibrationvaluesofaPXMultiSensorMk1onaPX
MultiSensorMk2,youmustonaportdoorsensorswitchthesignonrollvalueand
onthestarboardsensorswitchsignonYawvalue.
10SelectSettoacceptthevalues.
11Disconnectthesensorfromtheinterfacecableandthecomputer.
SimradPXMultiSensorMk2InstructionManual