Checkingthesensorsreadings
TheTV80offerstheMeasurementsdialogboxtoidentifythelatestreadingssentbyall
thesensorsinstalledandthequalityofthesereadings.
Prerequisites
TheTV80hasbeensetupwithitshardwareunitsconnectedasspeciedbytherelevant
installationinstructions.
Procedure
1Ontheprocessorunitdesktop,double-clicktheTV80icontostarttheprogram.
2SelecttheSetupicontoopenthemenu.
3OntheSetupmenu,selectInstallation.
4ObservetheI/OSetuppageontherightsideoftheInstallationdialogbox.
Everyinterfaceispresentedasasmall"blockdiagram".
5Selecttheinspectionpointattheleft
ofthe“blockdiagram”youwantto
check.
TheMeasurementsdialogboxopens.
6CheckiftheTV80isreceiving
informationfromaspecicsensor.
YoucanseeiftheTV80istakingthemeasurementasavalidvalue(“y”letter)
ornot(“n”letter).
7ObservethevaluegivenforeverymeasurementunderQualitytoverifythateach
sensorprovidestheexpectedinformation.
Relatedtopics
Troubleshooting,page36
Useandmaintenance,page23
SimradPXMultiSensorMk2InstructionManual