36
454200/A
Troubleshooting
Whendealingwithwirelesscatchmonitoringsensorsyoumayexperiencesomebad
readings,ornoreadingsatall.Therearesomecheckingsyoucandobeforecalling
thesupportdepartment.
Todosomeofthesetestsyoumayneed:
•OneorseveralPXMultiSensorChargers
•PXConguratorcable
•Multimeter
•AcomputerwiththeTV80programinstalled.
Symptom
ProbablecauseWhattodo
Corrodedwaterswitch.Inspectionandreplacementofthebrass
screw,page26
Dirtychargersockets.Cleaningthesensorchargersockets,
page24
Sensorcannot
beactivated
Flatbattery.Chargingthesensorbattery,page27
Checkingifthesensorchargesproperly,
page29
DefectivePX
MultiSensorCharger
MeasuringtheoutputvoltagesfromthePX
MultiSensorCharger,page30
Sensordoesnot
takecharge
Dirtychargersockets.Cleaningthesensorchargersockets,
page24
SimradPXMultiSensorMk2InstructionManual