454200/A
35
Checkingtherangesettingofameasurement
Whenacatchmonitoringsensortakesameasurementoutsidetherangevaluesdened,it
willnotbedisplayedorwillpresentanexceptionvalue.
Prerequisites
TheTV80hasbeensetupwithitshardwareunitsconnectedasspeciedbytherelevant
installationinstructions.
Context
Oncedenedthemeasurementsyouwantyourcatchmonitoringsensortomake,youcan
optimisetheirrangevaluesinordertogetabetterresolution.WiththeTV80youcan
deneaminimumandamaximumrangeforeverymeasurementintheAdvanceddialog
box.TheAdvanceddialogboxisopenedfromtherelevantConguratordialogboxes.
Procedure
1Ontheprocessorunitdesktop,double-clicktheTV80icontostarttheprogram.
2OntheSetupmenu,selectInstallation.
3IntheSensorlist,selectthesensoryouwanttocheckitscongurationparameters.
4SelectModifySensor.
5IntheveryrstPXSensorConguratordialogbox,selectcommunicationport
andsensortype,thenselectConnect.
TherelevantsensorConguratordialogboxopens.
6SelectAdvanced.
7Checkifthevaluesdenedfortheminimumandmaximumrangeareinsidethe
rangesetupforthatmeasurement.
8Ifnecessary,enternewvalues.
9SelectOKtoclosethedialogbox.
10Disconnectthesensorfromtheinterfacecableandthecomputer.