454200/A
25
•Pressurizedair
•Cleanandlintfreecloth
•Smallbrushorcottonswab
Procedure
1Usehighpressureairanddirectthenozzleintoeachofthesocket.Blowoutwater
andmoisture.
2Useasmallbrushoracottonswabandcleaneachsocketthoroughly.
3Wipeoffthesensorwithadrylintfreecloth.Payspecialattentiontothearea
closetothesensorsockets.
Relatedtopics
Troubleshooting,page36
Useandmaintenance,page23
Changingasinglepinonthechargerplug
Observethisproceduretochangeasingleplugontheonthebatterychargerconnector.
Ifadditionalpinsarerequired,youcanorderthese
fromSimrad.
Procedure
1Makesurethatthechargerisdisconnectedfrom
theACmainspower.
2Useaspanner,andunscrewthepinfromtheplug.
3Retrieveanewpinandscrewitintothesocket.
Important
Donotuseexcessiveforce.Maximumtorqueis1.5Nm.Werecommendyouthat
youtighteneachplugbyhandstoavoiddamage.
Relatedtopics
Troubleshooting,page36
Useandmaintenance,page23
Useandmaintenance