QA Full Inspection
Pa-50
22
Equipment
Audio Precision ATS-2 : Audio Analyzer
Please refer to each description for Audio Analyzer Setting.
Enter Test Mode
Please enter TEST MODE. After "Internal Inspection" completes, please press [F4] until
press key; -> LINE IN is displayed on LCD. After confirmation of Display, please press
[F3] and confirm the following LCD display.
Frequence Response Check
1. IN-OUT L 100[Hz]
Input Signal : INPUT L/MONO, 100[Hz], 1[Vrms]
Range : OUTPUT L/MONO, 100[Hz], -3.0 to -1.0[dBV]
2. IN-OUT L 1[KHz]
Input Signal : INPUT L/MONO, 1[KHz], 1[Vrms]
Range : OUTPUT L/MONO, 1[KHz], -3.0 to -1.0[dBV]
3. IN-OUT L 10[KHz]
Input Signal : INPUT L/MONO, 10[KHz], 1[Vrms]
Range : OUTPUT L/MONO, 10[KHz], -3.0 to -1.0[dBV]
4. IN-OUT R 100[Hz]
Input Signal : INPUT R, 100[Hz], 1[Vrms]
Range : OUTPUT R, 100[Hz], -3.0 to -1.0[dBV]
5. IN-OUT R 1[KHz]
Input Signal : INPUT R, 1[KHz], 1[Vrms]
Range : OUTPUT R, 1[KHz], -3.0 to -1.0[dBV]
7. IN-OUT R 10[KHz]
Input Signal : INPUT R, 10[KHz], 1[Vrms]
Range : OUTPUT R, 10[KHz], -3.0 to -1.0[dBV]