DSP-62-AEC, DSP-62-UC Protocol 3000
71
Function
Description
Syntax
Parameters/Attributes
Example
MODEL?
Get device model.
This command
identifies equipment
connected to
DSP-62-AEC and
DSP-62-UC and
notifies of identity
changes to the
connected equipment.
The Matrix saves this
data in memory to
answer REMOTE-
INFO requests.
COMMAND
#MODEL?<CR>
FEEDBACK
~nn@MODELmodel_name<CR><LF>
model_name String of up to 19
printable ASCII chars
Get the device model:
#MODEL?<CR>
NAME
Set machine (DNS)
name.
The machine name
is not the same as the
model name. The
machine name is used
to identify a specific
machine or a network
in use (with DNS
feature on).
COMMAND
#NAMEmachine_name<CR>
FEEDBACK
~nn@NAMEmachine_name<CR><LF>
machine_name String of up to 15
alpha-numeric chars (can include
hyphen, not at the beginning or end)
Set the DNS name of the
device to room-442:
#NAMEroom-442<CR>
NAME?
Get machine (DNS)
name.
The machine name
is not the same as the
model name. The
machine name is used
to identify a specific
machine or a network
in use (with DNS
feature on).
COMMAND
#NAME?<CR>
FEEDBACK
~nn@NAMEmachine_name<CR><LF>
machine_name String of up to 15
alpha-numeric chars (can include
hyphen, not at the beginning or end)
Get the DNS name of the
device:
#NAME?<CR>
NAME-RST
Reset machine (DNS)
name to factory
default.
Factory default of
machine (DNS) name
is “KRAMER_” + 4 last
digits of device serial
number.
COMMAND
#NAME-RST<CR>
FEEDBACK
~nn@NAME-RSTOK<CR><LF>
Reset the machine name (S/N
last digits are 0102):
#NAME-
RSTKRAMER_0102<CR>
NET-CONFIG
Set a network
configuration.
Parameters,[DNS1]
and [DNS2]are
optional.
For Backward
compatibility, the id
parameter can be
omitted. In this case,
the Network ID, by
default, is 0, which is
the Ethernet control
port.
If the gateway
address is not
compliant to the
subnet mask used for
the host IP, the
command will return
an error. Subnet and
gateway compliancy
specified by RFC950.
COMMAND
#NET-CONFIGid,ip,net_mask,gateway,[DNS1],[DNS2]<CR>
FEEDBACK
~nn@NET-CONFIGid,ip,net_mask,gateway<CR><LF>
id Network IDthe device network
interface (if there are more than one).
Counting is 0 based, meaning the
control port is ‘0’, additional ports are
1,2,3….
ip Network IP
net_mask Network mask
gateway Network gateway
Set the device network
parameters to IP address
192.168.113.10, net mask
255.255.0.0, and gateway
192.168.0.1:
#NET-CONFIG0,192.168.1
13.10,255.255.0.0,192.1
68.0.1<CR>
NET-CONFIG?
Get a network
configuration.
COMMAND
#NET-CONFIG?id<CR>
FEEDBACK
~nn@NET-CONFIGid,ip,net_mask,gateway<CR><LF>
id Network IDthe device network
interface (if there are more than one).
Counting is 0 based, meaning the
control port is ‘0’, additional ports are
1,2,3….
ip Network IP
net_mask Network mask
gateway Network gateway
Get network configuration:
#NET-CONFIG?id<CR>

Other manuals for Kramer DSP-62-AEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kramer DSP-62-AEC and is the answer not in the manual?

Kramer DSP-62-AEC Specifications

General IconGeneral
BrandKramer
ModelDSP-62-AEC
CategoryRecording Equipment
LanguageEnglish

Related product manuals