TP-578H - Protocol 3000
17
17
10 Protocol 3000
The TP-578H can be operated using serial commands from a PC, remote
controller or touch screen using the Kramer Protocol 3000.
This section describes the:
Kramer Protocol 3000 syntax (see Section 10.1)
Kramer Protocol 3000 commands (see Section 10.2)
10.1 Kramer Protocol 3000 Syntax
10.1.1 Host Message Format
Start
Address (optional)
Body
Delimiter
#
device_id@
Message
CR
10.1.1.1 Simple Command
Command string with only one command without addressing:
Start
Body
Delimiter
#
Command SP Parameter_1,Parameter_2,…
CR
10.1.1.2 Command String
Formal syntax with command concatenation and addressing:
Start
Address
Body
Delimiter
#
device_id@
Command_1 Parameter1_1,Parameter1_2,…|
Command_2 Parameter2_1,Parameter2_2,…|
Command_3 Parameter3_1,Parameter3_2,…|…
CR
10.1.2 Device Message Format
Start
Address (optional)
Body
delimiter
~
device_id@
Message
CR LF
10.1.2.1 Device Long Response
Echoing command:
Start
Address (optional)
Body
Delimiter
~
device_id@
Command SP [Param1 ,Param2 ] result
CR LF
CR = Carriage return (ASCII 13 = 0x0D)
LF = Line feed (ASCII 10 = 0x0A)
SP = Space (ASCII 32 = 0x20)