46
WP-5VH2 - Protocol 3000
Command - AUD-LVL
Command Type - Audio
Command Name
Permission
Transparency
Set:
AUD-LVL
End User
Public
Get:
AUD-LVL?
End User
Public
Description
Syntax
Set:
Set audio level in specific amplifier stage
#AUD-LVLstage, channel, volume
Get:
Get audio level in specific amplifier stage
#AUD-LVL? stage, channel
Response
~nn@AUD-LVLstage, channel, volume␍␊
Parameters
stage - ‘IN, ’OUT’ or numeric value of present audio processing stage
For example: ‘1’ for input level, ‘2’ for output
channel - input or output number
volume - audio parameter in Kramer units, minus sign precedes negative values.
++ increase current value,
-- decrease current value
Response Triggers
Notes