ADD FURNACE CO.,LTD.
44 ซอยบรมราชชนนี 

โทร: 02-888-3472 โท: ออกแบ:08-08-170-170 แฟกซ์: 02-888-3258
https://www.add-furnace.com E-mail: sales@add-furnace.com
IC 40 function > Parameters > Parameter sets
Parameter set Operating mode Function
P68025 9 2-point operation with switchover of the running times, running time: 4.5 s/15 s
P68026 21 2-point operation, running time: 7.5 s
P68027 22 2-point operation with switchover of the adjustment angle for the “open”
position, running time: 7.5 s
P68028 23 2-point operation with input-dependent adjustment angle for the “open”
position, running time: 7.5 s
P68029 24 2-point operation with switchover of the running times, running time: 4.5 s/ 15 s
P68030 25 2-point operation with characteristic curve switchover I, running time: 7.5 s
P68031 26 2-point operation with characteristic curve switchover II, running time: 7.5 s
55