EasyManua.ls Logo

Krom Schroder IC 20 - Running Times and Torques

Krom Schroder IC 20
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

ADD FURNACE CO.,LTD.
44 ซอยบรมราชชนนี 

โทร: 02-888-3472 โท: ออกแบ:08-08-170-170 แฟกซ์: 02-888-3258
https://www.add-furnace.com E-mail: sales@add-furnace.com
Technical data
9.3 Running times and torques
Type
Running time [s/90°]
Torque [Nm]
50 Hz
60 Hz
50 Hz
60 Hz
IC 20-07
7.5
6.25
2.5
2
IC 20-15
15
12.5
3
3
IC 20-30
30
25
3
3
IC 20-60
60
50
3
3
IC 40
4.5
76.5
4.5
76.5
2.5
2.5
IC 40S
4.5
76.5
4.5
76.5
3
3
IC 20:
The running time per 90° depends on the required torque.
The running time is reduced by a factor of 0.83 at 60 Hz.
IC 40:
On the IC 40, the running time and torque are independent
of the mains frequency. The running time can be freely pro-
grammed between the limits of 4.576.5 s.

Table of Contents

Other manuals for Krom Schroder IC 20

Related product manuals