Maintenance
54
Pos: 24.33.10 / BA/Wartung/Mä hwerke/Messerschr aub / Mess erschnellverschlus s/Messerschr aubverschluss Halt ebolzen 14 m m @ 0\mod_ 119726790737 5_78.docx @ 1 6425 @ @ 1
10.10.2 Blade screw connection
Danger! - Insufficient thickness of material on the retaining bolts.
Effect: Danger to life or serious injuries.
At every blade changing check the thickness of the holding bolts material.
Damage or worn retaining bolts must always be replaced by sets on each cutting
disc/blade drum!
The material thickness of the retaining bolts must not be less than 14 mm at the weakest
point.
EC-240-0
min. 14 mm
Fig. 30