EasyManuals Logo
Home>KSB>Water Pump>Delta Macro F

KSB Delta Macro F User Manual

KSB Delta Macro F
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
9 Trouble-shooting
52 of 92
KSB Delta Macro
1983.843/04-EN
A B C D E F G H I Possible cause Remedy
- - - - - - Temperature of power
electronics or stator winding
too high
Reduce the ambient temperature.
Improve ventilation.
Clean cooling fins.
Ensure that the intake opening for the fans is
not blocked.
Ensure that the fans are working properly.
Reduce the power input by changing the
operating point (system-specific).
Check the permissible load and, if necessary, use
external cooling.
- - - - - - - 24 V supply overloaded Disconnect frequency inverter from the power
supply and eliminate the cause of the overload.
- - - - - - - - Dry running Check the hydraulic system and rectify the fault on
the frequency inverter.
- - - - - - Sensor signal error (e.g.
broken wire)
Check sensor and sensor cable.
- - - - - - Phase failure (drive) Check motor connection and stator winding.