722 2-9-14-3 Fault pressure sensor discharge side Alert Manual
723 2-9-14-4 Broken wire pressure sensor discharge side Alert Manual
724 2-9-14-5 Broken wire pressure sensor discharge side Alert Manual
725 2-9-14-6 Discharge-side pressure too low too often Information Auto
726 2-9-14-7 Discharge-side pressure too high too often Information Auto
740 2-9-15-1 Fault pressure sensor at tank Alert Manual
741 2-9-15-2 Broken wire pressure sensor at tank Alert Manual
742 2-9-15-3 Short-circuit pressure sensor at tank Alert Manual
750 2-9-16-1 Fault pressure sensor at tank Alert Auto
751 2-9-16-2 Broken wire pressure sensor at tank Alert Auto
752 2-9-16-3 Short-circuit pressure sensor at tank Alert Auto
760 2-9-17-1 Fault temperature sensor Alert Auto
761 2-9-17-2 Temperature too high Alert Manual
762 2-9-17-3 Temperature too low Alert Manual
770 2-9-18-1 Leakage of pump system Alert Manual
10.3.3 Messages for specific functions
Table40: Messages for additional devices
ID
message
Parameter Description Status Reset mode
(factory
setting)
800 2-9-19-1 Lack of water Alert Manual
801 2-9-19-2 Dry running protection too often within time frame Information Auto
810 2-9-20-1 Fault rainwater pump 1 Alert Manual
811 2-9-20-2 Starts per hour exceeded rainwater pump 1 Warning Auto
812 2-9-20-3 Manual OFF rainwater pump 1 Warning Auto
813 2-9-20-4 Manual ON rainwater pump 1 Warning Auto
814 2-9-20-5 Fault rainwater pump 2 Alert Manual
815 2-9-20-6 Starts per hour exceeded rainwater pump 2 Warning Auto
816 2-9-20-7 Manual OFF rainwater pump 2 Warning Auto
817 2-9-20-8 Manual ON rainwater pump 2 Warning Auto
818 2-9-20-9 All rainwater pumps OFF Alert Auto
819 2-9-20-10 Lack of rainwater Warning Auto
820 2-9-20-11 Use of drinking water Information Auto
830 2-9-21-1 Tank fill level too low Alert Auto
831 2-9-21-2 Tank fill level critical Warning Auto
832 2-9-21-3 Tank fill level too high Alert Auto
833 2-9-21-4 Overflow of tank Alert Manual
835 2-9-21-5 Flushing of inlet line Information Auto
837 2-9-21-6 Flushing of inlet line incomplete Warning Manual
838 2-9-21-7 Fault inlet valve Alert Manual
839 2-9-21-8 Fault additional inlet valve Alert Manual
850 2-9-22-1 Water stagnation Warning Manual
851 2-9-22-2 Flushing Information Auto
852 2-9-22-3 Flushing too often Warning Manual
860 2-9-23-1 Pipe filling active Information Auto
861 2-9-23-2 Maximum pipe filling attempts exceeded Warning Auto
862 2-9-23-3 Pipe filling failed Alert Auto