10 Related Documents
66 of 92
KSB Delta Macro
1983.843/04-EN
Parameter Description Value range and dependencies Factory setting Access level Read Access level Write Re-start
required
1-3-7-2-4-2 Value at 0/4 mA If selection … = 0 mA … 20 mA 0 … value at 20
mA
Everybody Service -
1-3-7-2-4-3 Value at 20 mA - Value at 0/4 mA …
100 bar
Everybody Service -
10.2.1.4 Further configuration settings
Table28: Further configuration settings parameters
Parameter Description Value range and dependencies Factory setting Access level Read Access level Write Re-start
required
1-4 Field bus - - Everybody Nobody -
1-4-1 Modbus RTU Disabled Disabled Everybody Service Y
Enabled
1-4-2 Slave address 1 … 247 247 Everybody Service Y
1-4-3 Baud rate 9600 kBit/s 115200 kBit/s Everybody Service Y
19200 kBit/s
38400 kBit/s
57600 kBit/s
115200 kBit/s
1-4-4 Parity None Odd Everybody Service Y
Odd
Even
1-5 Bluetooth - - - - -
1-5-1 Time for login 0 … 600s 150s Everybody Service -
1-6 Display - - Everybody Nobody -
1-6-1 Time-out lighting - - Everybody Nobody -
1-6-1-1 Time-out display 0…24h 10min Everybody Service -
1-6-1-2 Time-out display when message
active
0 … 60min 10sec Everybody Service -
1-6-1-3 Display lock time 0 .. 24h 10min Everybody Service -
1-6-2 Units displayed - - Everybody Nobody -
1-6-2-1 Pressure bar bar Everybody Service -
PSI
1-6-2-2 Height cm cm Everybody Service -