19. EVAPORATIVE/EXHAUST EMISSION
CONTROL SYSTEM
19
-
3
SERVICE INFORMATION
GENERAL INSTRUCTIONS
• Do not smoke or allow flames or sparks near the working area.
• Note the locations of tubes for proper installation.
• Replace any damaged tube with a new one.
• Make sure to tighten the connector of each tube securely.
TOOLS
• Vacuum pump-A937Χ-014-ΧΧΧΧ
• Pressure pump-
SPECIFICATIONS
Purge control valve vacuum pressure 45mm/Hg
Charcoal canister capacity 90cc