EasyManua.ls Logo

Kyocera FS-920 - Page 55

Kyocera FS-920
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2GL/2FV/2FW
1-5-13
F010
(F1)
Code ROM checksum error (16/18
ppm printers only)
Checksum for the code ROM that
holds the system program is wrong.
Defective code
ROM (on-board).
Replace the main PWB. See page 1-6-16.
Defective PWB. Replace the main PWB. See page 1-6-16.
F020
(F2)
Memory check error
Access to the expansion memory
(DIMM) or RAM on the main PWB
failed.
Defective main
PWB.
Replace the main PWB. See page 1-6-15 or
1-6-16.
Defective expan-
sion memory
(DIMM).
(16/18 ppm print-
ers only)
Replace the expansion memory (DIMM).
See page 1-3-6.
F030
(F3)
Main PWB system error
The error pertaining to the system
occurred except the F0 (F010) condi-
tion.
Defective main
PWB.
Replace the main PWB. See page 1-6-15 or
1-6-16.
F040
(E0)
Main - Engine communication error
The communication breakdown
occurred between the main PWB and
the engine/high voltage PWB during
the predetermined period in seconds.
Defective engine/
high voltage PWB.
Replace the engine/high voltage PWB. See
page 1-6-17.
Defective main
PWB.
Replace the main PWB. See page 1-6-15 or
1-6-16.
F050
(E6)
Engine checksum error
Checksum result failed with the CPU
and engine/high voltage PWB.
Defective engine/
high voltage PWB.
Replace the engine/high voltage PWB. See
page 1-6-17.
Code Contents
Remarks
Causes Check procedures/corrective measures