Appendix: SP Mode Tables
37
Engine Maintenance
Displays the current model in a dropdown list.
Do not change this setting (Designed for Factory Use).
Brand ID
00* – 7F
Displays the current brand ID number.
Do not change this setting (Designed for Factory Use).
LSU Adjustment
Input 160 bytes
setting.
Character: alphanumeric "0-9", "a-f", "A-F", only
valid data can be input.
Input length: 160 bytes
Trans. Belt Adjust
When you execute "Trans. Belt Adjust", the transfer belt adjustment is
done. This calibrates the motor speed to match the length of the new
transfer belt.
Fuser SC Detect On/Off*
If On, the engine detects SC559. If Off, the engine
does not detect "Fusing SC Reset".
Color
Registration
The engine will do color registration and density tuning automatically.
The machine will warm up automatically after this setting is changed.
Reset Transfer
Unit Life Counter
Resets the transfer unit life counter.
Fuser SC Reset This button is for resetting an SC related with the fusing errors.
Special Mode
This adjusts the M/A of toner.
[0 to 0x7F]
0x00: Normal (Default: no reduction)
0x06: 20% reduction
0x07: 10% reduction
Scan Maintenance
Mono
Compression
Setting
Sets the monochrome compression type for scanning.
MH (Default)/ MR/ MMR