3-192
Enhancement device setup procedure > Optional device installation
[CONFIDENTIAL]
157
Remove wrench [A] (Screw x1). The screw will use in step 157.
158
Adjust the height.
1 Loosen 2 screws [B] on the right front and rear of DF-9100. Turning the bolt [C] clockwise with the wrench [A]
makes DF-9100 unit higher and counterclockwise makes it lower.
2 Secure 2 screws [B].
[A]
[B]
[A]
[C]
[B]