5-8
Corrective action when service call occur > C2100
[CONFIDENTIAL]
5 - 3 C2260
Check the condition of the sensor by U704 and compare with the following combination. Then, adjust the unit position
that has a gap.
(1) Setup position
No Item Description Status
1 WC HP Treatment carriage HP sensor ON
2 WC Treatment carriage head lower sensor OFF
3 Cap Unit HP Treatment cap HP sensor ON
4 WL HP Treatment lift HP sensor ON
5 WL Cap Carry Treatment lift cap conveying sensor OFF
6 WL Cap Treatment lift cap position sensor OFF
7 WL Wipe Treatment lift wipe position sensor OFF
8 Wipe HP Wiping blade HP sensor ON
9 Wipe Start Wiping blade start position sensor OFF
10 Gap Adj 1 Discharge distance adjust sensor ON
11 Gap Adj 2 Discharge distance adjust sensor OFF
12 Gap Adj 3 Discharge distance adjust sensor OFF
13 Gap Adj 4 Discharge distance adjust sensor OFF
14 FU Upper 1 Image conveying upper limit sensor 1 OFF
15 FU Upper 2 Image conveying upper limit sensor 2 OFF
16 FU Pull Image conveying unit-out position sensor ON or OFF
17 FU Lower Image conveying lower limit sensor OFF
18 FU Reverse Image conveying unit lift wire reverse sensor OFF