FP+ Series Operation Manual 31
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
0 0 0 0 0
139 0 139 475 120
16 ! / Ch. 660
x4
32 ! / Bridged 1320
x2
8 ! / Ch. 1300
x4
16 ! / Bridged 2600
x2
4 ! / Ch. 2100
x4
8 ! / Bridged 4200
x2
2 ! / Ch. 2500
x4
4 ! / Bridged 5000
x2
16 ! / Ch. 660
x4
32 ! / Bridged 1320
x2
8 ! / Ch. 1300
x4
16 ! / Bridged 2600
x2
4 ! / Ch. 2100
x4
8 ! / Bridged 4200
x2
2 ! / Ch. 2500
x4
4 ! / Bridged 5000
x2
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
Pink noise
(1/4 rated
power) *3)
Pink noise
(1/8 rated
power)
Standby w. remote Power Off via NomadLink
30 A, Nema L5-30P Twist lock
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power.
Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if
operation is in excess of max. ratings.
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified
here is what is known as the "Active Power" of the amplifier providing useful, real-world values of power consumption and heat dissipation.
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
0 0 0 0 0
134 0 134 456 11 5
16 ! / Ch. 320
x4
32 ! / Bridged 640
x2
8 ! / Ch. 625
x4
16 ! / Bridged 1250
x2
4 ! / Ch. 1250
x4
8 ! / Bridged 2500
x2
2 ! / Ch. 1500
x4
4 ! / Bridged 3000
x2
16 ! / Ch. 320
x4
32 ! / Bridged 640
x2
8 ! / Ch. 625
x4
16 ! / Bridged 1250
x2
4 ! / Ch. 1250
x4
8 ! / Bridged 2500
x2
2 ! / Ch. 1500
x4
4 ! / Bridged 3000
x2
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power.
Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if
operation is in excess of max. ratings.
Pink noise
(1/4 rated
power) *3)
Pink noise
(1/8 rated
power)
Standby w. remote Power Off via NomadLink
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified
here is what is known as the "Active Power" of the amplifier providing useful, real-world values of power consumption and heat dissipation.
30 A, Nema L5-30P Twist lock