EasyManuals Logo

Lab.gruppen FP+ series User Manual

Lab.gruppen FP+ series
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
FP+ Series Operation Manual 31
APPENDIX 8
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
0 0 0 0 0
139 0 139 475 120
16 ! / Ch. 660
x4
32 ! / Bridged 1320
x2
8 ! / Ch. 1300
x4
16 ! / Bridged 2600
x2
4 ! / Ch. 2100
x4
8 ! / Bridged 4200
x2
2 ! / Ch. 2500
x4
4 ! / Bridged 5000
x2
16 ! / Ch. 660
x4
32 ! / Bridged 1320
x2
8 ! / Ch. 1300
x4
16 ! / Bridged 2600
x2
4 ! / Ch. 2100
x4
8 ! / Bridged 4200
x2
2 ! / Ch. 2500
x4
4 ! / Bridged 5000
x2
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
825
2817
710
52,9
27,6
4159
3333
Pink noise
(1/4 rated
power) *3)
13,6
2800
789
2691
678
263
897
226
1733
363
1238
312
39,4
20,6
3589
1164
7,1
1143
22,4
11,7
2096
880
3973
1001
32,2
16,8
2414
1250
Pink noise
(1/8 rated
power)
10,7
1050
864
2949
743
1371
345
1958
493
1224
330
402
5,6
650
574
13,5
1914
Standby w. remote Power Off via NomadLink
Power On, Idling
Amp
W
732
16,9
8,8
16 A, CEE7
30 A, Nema L5-30P Twist lock
FP 10000Q
Level
Load
Rated
Power
Line Current *2)
Watt *1)
Thermal Dissipation
25,9
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power.
Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if
operation is in excess of max. ratings.
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified
here is what is known as the "Active Power" of the amplifier providing useful, real-world values of power consumption and heat dissipation.
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
0 0 0 0 0
134 0 134 456 11 5
16 ! / Ch. 320
x4
32 ! / Bridged 640
x2
8 ! / Ch. 625
x4
16 ! / Bridged 1250
x2
4 ! / Ch. 1250
x4
8 ! / Bridged 2500
x2
2 ! / Ch. 1500
x4
4 ! / Bridged 3000
x2
16 ! / Ch. 320
x4
32 ! / Bridged 640
x2
8 ! / Ch. 625
x4
16 ! / Bridged 1250
x2
4 ! / Ch. 1250
x4
8 ! / Bridged 2500
x2
2 ! / Ch. 1500
x4
4 ! / Bridged 3000
x2
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power.
Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if
operation is in excess of max. ratings.
872
2977
750
38,9
19,4
2872
2000
Pink noise
(1/4 rated
power) *3)
11,8
1667
833
37,3
18,6
2748
1081
3690
930
344
1175
296
569
1942
489
825
5,9
771
20,0
10,0
1402
427
2817
710
22,8
11,4
1575
750
Pink noise
(1/8 rated
power)
6,9
3,5
625
590
2015
508
898
226
313
388
1323
333
5,4
700
160
263
18,0
9,0
1215
Standby w. remote Power Off via NomadLink
Power On, Idling
Amp
W
423
10,9
FP 6000Q
Level
Load
Rated
Power
Line Current *2)
Watt *1)
Thermal Dissipation
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified
here is what is known as the "Active Power" of the amplifier providing useful, real-world values of power consumption and heat dissipation.
16 A, CEE7
30 A, Nema L5-30P Twist lock

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lab.gruppen FP+ series and is the answer not in the manual?

Lab.gruppen FP+ series Specifications

General IconGeneral
SeriesFP+
Total Harmonic Distortion<0.1%
Damping Factor>500
Dimensions88mm x 483mm x 400mm (HxWxD)
Weight12.5kg
TypeAmplifier
Output VoltageVaries by model
Input Impedance20 kOhm balanced
Gain32dB
Power ConsumptionVaries by model
Power Output2 x 1300W @ 4Ω, 2 x 800W @ 8Ω
Power SupplyUniversal, regulated switch mode power supply

Related product manuals