PLM Series Quick Start and Field Reference Guide 7
INSTALLATON 5
5.4 Cooling
The PLM uses a forced-air cooling system with
airflow from front to rear, allowing high continuous
power levels without thermal problems. (Front-to-rear
airflow is preferable as air at the front of a rack is
cooler than that at the rear in nearly all situations.)
Never attempt to reverse the airflow. The operation
of the PLM’s cooling system is dependent on front-
to-rear airow; it will not function effectively with
airflow in the opposite direction.
Make sure an adequate air supply is provided in
front of the PLM, and that the rear of the PLM has
sufficient space to allow the exit air to escape. If the
PLM is rack-mounted, never operate the unit with
any front or rear rack doors or covers in position.
Also note that any unused rack spaces should have
solid blanks tted (not ventilation blanks) to ensure
efficient air circulation. Leaving gaps in between
items of equipment degrades the effectiveness of
forced-air cooling.
If installing one or more PLM’s in a rack with other
fan-cooled equipment, be sure that all the other
units also use front-to-rear airow for cooling. If
this precaution is not observed, there is a risk of
overheating, as units with the reverse airflow will
be drawing in air which has already been heated by
the PLMs.
The PLM is equipped with a sophisticated
temperature sensing system which protects
it from any overheating which may occur as
a result of inadequate ventillation. Should a power
output channel overheat, the temperature sensing
circuits will mute that channel until the temperature
reduces to a safe level. If the power supply overheats,
another sensing circuit will mute all channels until
the power supply temperature reduces to a safe
operating level.
Always make sure that the dust filters behind the
detachable front panel are clean to ensure maximum
possible airow.
If the device malfunctions as a result of dirty
dust filters, any required repairs are not cov-
ered by the warranty.
Figure 5.3b : Use tube for slide-on installation
Figure 5.3a : Use washer for xed installation

Other manuals for Lab.gruppen PLM Series PLM 10000Q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lab.gruppen PLM Series PLM 10000Q and is the answer not in the manual?

Lab.gruppen PLM Series PLM 10000Q Specifications

General IconGeneral
Output Power (per channel at 2 ohms)2500 W
Output Power (per channel at 4 ohms)2300 W
Output Power (per channel at 8 ohms)1250 W
Output Power (per channel at 16 ohms)625 W
Total Output Power10000 W
Number of channels4
Sample Rate96 kHz
Latency1.5 ms
THD+N<0.1%
Damping Factor> 500
Dimensions88 x 483 x 396 mm
Coolingfront-to-rear airflow
ProtectionDC, thermal, short circuit
ConnectorsSpeakON
Voltage100-240 V AC
Signal to Noise Ratio>112 dBA
Input Impedance20k ohms (balanced), 10k ohms (unbalanced)