18 • ROUTINE MAINTENANCE
18.2 • PLACEMENT OUT OF SERVICE
If the appliance won’t be used for a long
period of time (more than a week), it is
advisable to proceed as follows.
a) If the appliance is equipped with Aroma
& Smoke, before cleaning, remove the
cartridges, insert the small tube in a
container full of water and run a few smoke
and aroma cycles so as to clean the tubes.
b) Run a cleaning cycle (with Calout)* at
a suitable level to ensure the utmost
cleanliness of the chamber. If the level is
not reached, run a new cleaning cycle, this
time without calout*.
c) Remove the can of detergent and run a
Soft cleaning cycle, using only water (use
an old can filled with water, and remember
to remove it at the end).
d) Remove the partitions and unhook the air
deflector in the chamber to inspect the rear
area and check for any dirt deposits, which
need to be removed.
e) Close the water supply valves
f) Open the settings menu and select the
boiler* menu, then the boiler emptying
command and wait for the operation to be
completed.
g) Disconnect the water supply tubes.
h) Turn the appliance off by pressing the on
button for 5 seconds.
i) Remove the shower and press the key to
drain any water left in the circuit (bring the
grip down to floor level).
j) Disconnect the power supply and pull out
the plug
k) Close the gas shut-off valve
l) Disconnect the drain tube to prevent
any odours or bacteria from entering the
appliance
m) Leave the door ajar.
n) If a Brita filter is installed, disconnect
it from the line, the filter will need to be
replaced in the event of long-term non-use
(max. 1 year after installation).
o) Check the wear status of the gaskets so
as to arrange for their replacement before
operation is resumed.
p) Protect the appliance against frost to
avoid error messages when it is turned
back on.
* Indication only applies to units equipped
with boiler or Calout system
90037400rev00

Table of Contents

Other manuals for Lainox Naboo boosted

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lainox Naboo boosted and is the answer not in the manual?

Lainox Naboo boosted Specifications

General IconGeneral
BrandLainox
ModelNaboo boosted
CategoryOven
LanguageEnglish

Related product manuals