LTI TruPulse 360R User’s Manual Page 45
Copyright (c) [2017] Laser Technology, Inc. All Rights Reserved. Unauthorized duplication, in whole or in part, is strictly prohibited.
Height (HT) Download Messages
$PLTIT,HT,HTvalue,units,*csum
<CR><LF>
where:
$PLTIT, is the Criterion message identifier.
HT, Height message type.
HTvalue, Calculated Height. Two decimal places.
units, F=feet Y=yards M=meters
Note: Only International lasers include meters.
*csum An asterisk followed by a hexadecimal checksum.
The checksum is calculated by XORing all the
characters between the dollar sign and the asterisk.
<CR> Carriage return.
<LF> Optional linefeed.
Example:
$PLTIT,HT,22.10,F*0C