Hybrid Servo Hardware Installation Manual
17
HWMN
-
HBS
-
R20120
411
Position Following Error Protection
When the position error exceeds the limit (software configurable, see software manual), position,
protection will be activated and red LED will blink seven times within each periodic time.
Frequently Asked Questions
In the event that your drive doesnt operate properly, the first step is to identify whether the problem
is electrical or mechanical in nature. The next step is to isolate the system component that is causing
the problem. As part of this process you may have to disconnect the individual components that
make up your system and verify that they operate independently. It is important to document each
step in the troubleshooting process. You may need this documentation to refer back to at a later date,
and these details will greatly assist our Technical Support staff in determining the problem should you
need assistance.
Many of the problems that affect motion control systems can be traced to electrical noise, controller
software errors, or mistake in wiring.
Problem Symptoms and Possible Causes
Symptoms Possible Problems
No power
Microstep resolution setting is wrong
Fault condition exists
Motor is not rotating
The drive is disabled
Motor rotates in the
wrong direction
The Direction signal level is reverse
Power supply voltage beyond drives input range
Something wrong with motor coil
The Drive In Fault
Wrong connection
Control signal is too weak
Control signal is interfered
Something wrong with motor coil
Motor is undersized for the application
Acceleration is set too high
Erratic Motor Motion
Power supply voltage too low
Inadequate heat sinking / cooling Excessive motor and
drive heating
Load is too high