GENERAL RULES FOR INSTALLATION
Maximum distance between EP or
handset and power supply.
In the riser, the quantity of devices
managed by a power supply are
shown in table 4, table 5, and table 6.
Notes:
1. The current can also be affected by the distance.
Here every floor is supposed to be 5 m height.
2. If there are many 323002, it is supposed that the
distance of 323002is 0.5 m.
Case 1, case 2, case 3, case 4, case 7,
case 8, case 9 are for 323005(PW1)
and 323010(aPW1). Case 4, case 5,
case 6, case 10, case 11, case 12 are
for 323005(PW1).
How many apartments
on every oor
HANDSET
Case 1 Case 2 Case 3 Case 4
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
2 apartments/oor
(Don’t use extra power cable)
24 max: 12 oors 4 max: 2 oors 16 max: 8 oors 10 [*1] max: 5 oors
2 apartments/oor
(use extra power cable)
78 max: 39 oors - - 16 max: 8 oors 20 [*1] max: 10 oors
4 apartments/oor
40 max: 10 oors 4 max: 1 oor 16 max: 4 oors 12 [*1] max: 3 oors
8 apartments/oor
56 max: 7 oors 4 max: 1 oor 16 max: 2 oors 12 [*1] max: 2 oors
12 apartments/oor
56 max: 5 oors 4 max: 1 oor 16 max: 2 oors 12 [*1] max: 1 oor
16 apartments/oor
56 max: 4 oors 4 max: 1 oor 16 max: 1 oor 16 [*1] max: 1 oor
20 apartments/oor
68 max: 4 oors 4 max: 1 oor 16 max: 1 oor 20 [*1] max: 1 oor
24 apartments/oor
68 max: 3 oors 4 max: 1 oor 16 max: 1 oor 20 [*1] max: 1 oor
28 apartments/oor
68 max: 3 oors 4 max:1 oor 16 max: 1 oor 20 [*1] max: 1 oor
32 apartments/oor
68 max: 3 oors 4 max:1 oor 16 max: 1 oor 20 [*1] max: 1 oor
36 apartments/oor
68 max: 2 oors 4 max:1 oor 16 max: 1 oor 20 [*1] max: 1 oor
Table 4: case 1 to case 4, the quantity of devices managed by 323005 (PW1).
Table 5: case 1 to case 4, the quantity of devices managed by 323005 (Power supply).
How many apartments
on every oor
handSet
Case 5 Case 6 Case 7 Case 8
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
2 apartments/oor
(Don’t use extra power cable)
4 [*2] max:2 oor 8 [*2] max:4 oor 36 max: 18 oors 8 max: 4 oors
2 apartments/oor
(use extra power cable)
8 [*2] max: 4 oors 90 max: 45 oors 8 max: 4 oors
4 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 56 max: 14 oors 8 max: 2 oors
8 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 72 max: 9 oors 8 max: 1 oor
12 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 76 max: 7 oors 8 max: 1 oor
16 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 80 max: 5 oors 8 max: 1 oor
20 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 80 max: 4 oors 8 max: 1 oor
24 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 80 max: 4 oors 8 max: 1 oor
28 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 80 max: 3 oors 8 max: 1 oor
32 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 80 max: 3 oors 8 max: 1 oor
36 apartments/oor
4 [*2] max: 1 oor 8 [*2] max: 1 oor 80 max: 3 oors 8 max: 1 oor
Power supply check and calculation