Table 6: case 9 to case 12, the quantity of devices managed by 323005 (Power supply).
How many apartments
on every oor
handSet
Case 9 Case 10 Case 11 Case 12
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
Total Qty of
handsets
Floor limit
2 apartments/oor
(Don’t use extra power cable)
16 max: 8 oors 16 [*2] max: 16 oors 4 [*3] max: 1 oor 12 [*1] max: 6 oors
2 apartments/oor
(use extra power cable)
16 max: 8 oors 36 [*3] max: 6 oors 4 [*3] max: 1 oor 12 [*1] max: 6 oors
4 apartments/oor
16 max: 4 oors 24 [*3] max: 4 oors 4 [*3] max: 1 oor 12 [*1] max: 3 oors
8 apartments/oor
16 max: 2 oors 32 [*3] max: 3 oors 4 [*3] max: 1 oor 12 [*1] max: 2 oors
12 apartments/oor
16 max: 2 oors 36 [*3] max: 3 oors 4 [*3] max: 1 oor 12 [*1] max: 1 oor
16 apartments/oor
16 max: 1 oor 36 [*3] max: 2 oors 4 [*3] max: 1 oor 12 [*1] max: 1 oor
20 apartments/oor
16 max: 1 oor 36 [*3] max: 2 oors 4 [*3] max: 1 oor 12 [*1] max: 1 oor
24 apartments/oor
16 max: 1 oor 36 [*3] max: 2 oors 4 [*3] max: 1 oor 12 [*1] max: 1 oor
28 apartments/oor
16 max: 1 oor 36 [*3] max: 2 oors 4 [*3] max: 1 oor 12 [*1] max: 1 oor
32 apartments/oor
16 max: 1 oor 36 [*3] max: 2 oors 4 [*3] max: 1 oor 12 [*1] max: 1 oor
36 apartment/oor
16 max: 1 oor 36 [*3] max: 1 oor 4 [*3] max: 1 oor 12 [*1] max:1 oor
Remark: In table 4, table 5 and table 6 , in case 4, case 5, case 6, case 10, case 11 and case 12, the quantity of handsets is only for 323005.
If using 323010, Please refer to table 7;
*1: 2 small EP and 1 EP can work at the
same time with handsets connected
to the same power supply.
*2: 1 small EP and 1 EP can work at the
same time with handsets connected
to the same power supply.
*3: 3 small EP and 1 EP can work at the
same time with handsets connected
to the same power supply.
The information of table 4 to table 6
is based on the below conditions:
A) 50 m cable from Floor shunt
to handset.
B) 5 m cable between floors.
C) 0.5 m cable between Floor shunt
and Floor shunt in same floor for
the projects with more than one
floor shunt on each floor.
D) Between Power supply and 1st
Floor shunt, for the connection
use 2 wire cables.
E) The data in above table also
limited by distance. Example: 4
apartment on every floor. Case 1.
can have 40 handsetsand the Max.
per floor is 10. In other words, the
distance must less than 45 m,
45 m= [(40/4)-1]*5.
65