Voltage V~
Frequency Hz
Power consumption W
Temperature °C
Airflow (50-100%) l/min.
Drive speed m/min.
Noise emission level L
pA
(dB)
Dimensions mm
Weight kg
TECHNICAL DATA
230 # 120 # 100 #
50 / 60 50 / 60 50 / 60
2300 1800 1500
20 – 620 20 – 620 20 – 620
max. 300 max. 250 max. 250
1.0 – 7.5 1.0 – 7.5 1.0 – 7.5
67 65 65
420×270×210 420×270 ×210 420×270 ×210
11.5 11.5 11.5
# Mains voltage is not reversible
CCA certified
Protection Class Ι
FI
230
120
WARNING
CAUTION
Approval Marks
2
Danger! Unplug the tool before opening it, as live compo-
nents and connections are exposed.
Incorrect use of hot air tools can present a fire and explosion
hazard, particularly in the proximity of flammable materials
and explosive gases.
The tool must be operated under supervision.
Heat can ignite flammable materials which are not in view.
For personal protection, we strongly recommend the tool to
be connected to an RCCB (Residual Current Circuit Breaker)
before using it on construction sites.
The rated voltage stated on the tool must correspond with
the mains voltage.
Danger of getting burned! Do not touch the end of the
heater tube and nozzle when they are hot. Let the tool
cool down. Do not point the hot air flow in the direction of
people or animals.
Protect the tool from damp and wet.
Connect tool to a receptacle with protective earth terminal.
Any disconnection of the protective conductor in or outside
the tool is dangerous!
Only use extension lead with protective conductor.