Page 32/95
21January2021/Version 0
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
Table 1: Ports definition
Low side mounting High side mounting
MU
1 2
3
4
5 6
Supply
Eth Com
Data
SU
SU
I2 VP I1 VN
Com
MU
+
-
Direct current flow / Stromfluss Normal / Courant direct
MU
1 2
3
4
5 6
Reserved
Supply
Eth Com
Data
SU
SU
I1 VP I2 VN
Com
MU
+
-
Reverse current flow / Stromfluss Revers / Courant indirect
MU
1 2
3 4 5 6
Supply
Eth Com
Data
SU
SU
I1 VP I2 VN
Com
+
-
Direct current flow / Stromfluss Normal / Courant direct
MU
1 2
3 4 5 6
Reserved
Supply
Eth Com
Data
SU
SU
I2 VP I1 VN
Com
+
-
Reverse current flow / Stromfluss Revers / Courant indirect
Figure 16: Connection and wiring diagrams
1
Power Supply +
2 Power Supply −
3 Reserved
4 Reserved
5 Reserved
6 Reserved
Eth Ethernet port
COM Data link port
VP
Voltage measurement +
VN Voltage measurement −