• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See
Chapter 4 “Parts listing, Lenovo System x3550 M3 Type 4254 and 7944” on page 403 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
• For additional memory troubleshooting information, refer to the “Troubleshooting Memory - IBM
BladeCenter and System x” document at
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-
5081319
.
• Go to the IBM support website at
http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
Action
3. Return the removed DIMMs, one at a time, to their original connectors,
restarting the server after each DIMM, until a DIMM fails. Replace each failing
DIMM with an identical known good DIMM, restarting the server after each
DIMM replacement. Repeat step 3 until you have tested all removed DIMMs.
4. Replace the DIMM with lit error LED; then, restart the server. Repeat as
necessary.
5. Reverse the DIMMs between the channels (of the same microprocessor), and
then restart the server. If the problem is related to a DIMM, replace the failing
DIMM.
6. (Trained service technician only) Install the failing DIMM into a DIMM connector
for microprocessor 2 (if installed) to verify that the problem is not the
microprocessor or the DIMM connector.
7. (Trained service technician only) Replace the system board.
Microprocessor problems
Use this information to solve microprocessor problems.
Chapter 3. Diagnostics 369