Figure 114. Operator information panel assembly cable connection
Step 4. Install the cover (see
“Installing the cover” on page 425).
Step 5. Slide the server into the rack.
Step 6. Reconnect the power cords and any cables that you removed.
Step 7. Turn on the peripheral devices and the server.
Removing and replacing FRUs
FRUs must be replaced or installed only by trained service technicians.
Note: The illustrations in this document might differ slightly from the hardware.
Removing the 240 VA safety cover
Use this information to remove the 240 VA safety cover.
To remove the 240 VA safety cover, complete the following steps:
Step 1. Read the safety information that begins on
“Safety” on page v and “Installation guidelines” on page
417
.
Step 2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3. Remove the cover (see
“Removing the cover” on page 424).
Step 4. Remove the SAS/SATA riser-card assembly (see
“Removing the SAS/SATA RAID riser-card
assembly” on page 450
).
Step 5. Remove the screw from the safety cover.
Chapter 5. Removing and replacing components 497