“Multiple drives are offline” on page 173
“A replacement drive does not rebuild” on page 173
“Green drive activity LED does not represent actual state of associated drive” on page 173
“Yellow drive status LED does not represent actual state of associated drive” on page 173
Server cannot recognize a drive
Complete the following steps until the problem is solved.
1. Observe the associated yellow drive status LED. If the LED is lit, it indicates a drive fault.
2. If the status LED is lit, remove the drive from the bay, wait 45 seconds, and reinsert the drive, making
sure that the drive assembly connects to the drive backplane.
3. Observe the associated green drive activity LED and the yellow status LED and perform corresponding
operations in different situations:
If the green activity LED is flashing and the yellow status LED is not lit, the drive is recognized by the
controller and is working correctly. Run the diagnostics tests for the drives. When you start a server
and press the key according to the on-screen instructions, the LXPM is displayed by default. (For
more information, see the “Startup” section in the LXPM documentation compatible with your server
at
https://pubs.lenovo.com/lxpm-overview/.) You can perform drive diagnostics from this interface.
From the Diagnostic page, click Run Diagnostic Disk Drive Test.
If the green activity LED is flashing and the yellow status LED is flashing slowly, the drive is
recognized by the controller and is rebuilding.
If neither LED is lit or flashing, check whether the drive backplane is correctly seated. For details, go
to step 4.
If the green activity LED is flashing and the yellow status LED is lit, replace the drive.
4. Make sure that the drive backplane is correctly seated. When it is correctly seated, the drive assemblies
correctly connect to the backplane without bowing or causing movement of the backplane.
5. Reseat the backplane power cable and repeat steps 1 through 3.
6. Reseat the backplane signal cable and repeat steps 1 through 3.
7. Suspect the backplane signal cable or the backplane:
Replace the affected backplane signal cable.
Replace the affected backplane.
8. Run the diagnostics tests for the drives. When you start a server and press the key according to the on-
screen instructions, the LXPM is displayed by default. (For more information, see the “Startup” section in
the LXPM documentation compatible with your server at
https://pubs.lenovo.com/lxpm-overview/.) You
can perform drive diagnostics from this interface. From the Diagnostic page, click Run Diagnostic
Disk Drive Test.
Based on those tests:
If the backplane passes the test but the drives are not recognized, replace the backplane signal cable
and run the tests again.
Replace the backplane.
If the adapter fails the test, disconnect the backplane signal cable from the adapter and run the tests
again.
If the adapter fails the test, replace the adapter.
Multiple drives fail
Complete the following steps until the problem is solved:
172
ThinkEdge SE350 V2 Hardware Maintenance Guide