48
4Q
-
DC
Chopper
520
series
4.2.6
CONTROLLER
ENABLE
(RFR)
16 17
PE
If
switch
RFR is
closed,
the controller
is
enabled.
If
switch
RFR is
open,
the
outputs
——
of
speed
and
current
controller
and
the
RFR\~
-
driver control
signals
are
set to 0V.
Use
bw
current contacts
20V11
mA
4.2.7
QUICK
STOP
QSP
If
switch
QSP
is
closed,
the
drive
is
decelerated
to
standstill
at rated
current.
The
chopper reference
inputs
are
reset. If
the
resistors
R39
(522
E)
or
R44
(524
E)
are
removed,
the
integral
component
of
the
QSP
speed
controller
is
not
inhibited
when
cbosing
switch
QSP.
Operating
the
chopper
with
zero
speed
after
the braking
phase
using
QSP
is
only
possible, if
the
speed
references
are
set to
0V
and
switch
QSP
is
cbosed.
The
kinetic energy
of
the
drive
is fed
into
the
DC
bus.
The
energy
must
be
dissipated
via
a
brake
resistor
or,
in
a
DC
bus
network,
fed
into
a
controller
which
is
operating
in
the
motor
mode.
Use
10w
current contacts
20V/1
mA
Lenze