EasyManua.ls Logo

Lenze 9300 - Page 14

Lenze 9300
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
3-3
BA9300POS EN 2.3
3.3 Rated data
3.3.1 Types 9321 to 9325
Type EVS9321-EP EVS9322-EP EVS9323-EP EVS9324-EP EVS9325-EP
Order No. EVS9321-EP EVS9322-EP EVS9323-EP EVS9324-EP EVS9325-EP
Type EVS9321-CP EVS9322-CP EVS9323-CP EVS9324-CP EVS9325-CP
Order No. EVS9321-CP EVS9322-CP EVS9323-CP EVS9324-CP EVS9325-CP
Mains voltage V
r
[V] 320 V - 0 %
V
r
528V+0%; 45Hz-0%... 65Hz+ 0%
Alternative DC supply V
DC
[V] 460 V - 0 %
V
DC
740 V + 0 %
Mains current with mains filter
Mains current without mains filter
I
r
[A] 1.5
2.1
2.5
3.5
3.9
5.5
7.0
-
12.0
16.8
Ratings for operation at a mains: 3 AC / 400V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW] 0.37 0.75 1.5 3.0 5.5
p
(
p
)
P
r
[hp] 0.5 1.0 2.0 4.0 7.5
Output power U, V, W (8kHz*) S
r8
[kVA] 1.0 1.7 2.7 4.8 9.0
Output power + U
DC
,-U
DC
2)
P
DC
[kW] 2.0 0.75 2.2 0.75 0
Output current (8 kHz*) I
r8
[A] 1.5 2.5 3.9 7.0 13.0
Output current (16 kHz*) I
r16
[A] 1.1 1.8 2.9 5.2 9.7
Max. output current (8 kHz*)
1)
I
max8
[A] 2.3 3.8 5.9 10.5 19.5
Max. output current (16 kHz*)
1)
I
max16
[A] 1.7 2.7 4.4 7.8 14.6
Max. standstill current (8 kHz*) I
08
[A] 2.3 3.8 5.9 10.5 19.5
Max. standstill current (16 kHz*) I
016
[A] 1.7 2.7 4.4 7.8 14.6
Ratings for operation at a mains: 3 AC / 480V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW] 0.37 0.75 1.5 3.0 5.5
p
(
p
)
P
r
[hp] 0.5 1.0 2.0 4.0 7.5
Output power U, V, W (8kHz*) S
r8
[kVA] 1.2 2.1 3.2 5.8 10.8
Output power + U
DC
,-U
DC
2)
P
DC
[kW] 2.0 0.75 2.2 0.75 0
Output current (8 kHz*) I
r8
[A] 1.5 2.5 3.9 7.0 13.0
Output current (16 kHz*) I
r16
[A] 1.1 1.8 2.9 5.2 9.7
Max. output current (8 kHz*)
1)
I
max8
[A] 2.3 3.8 5.9 10.5 19.5
Max. output current (16 kHz*)
1)
I
max16
[A] 1.7 2.7 4.4 7.8 14.6
Max. standstill current (8 kHz*) I
08
[A] 2.3 3.8 5.9 10.5 19.5
Max. standstill current (16 kHz*) I
016
[A] 1.7 2.7 4.4 7.8 14.6
Motor voltage V
M
[V] 0-3
×
V
Mains
Power loss (operation with I
ratedx
) P
loss
[W] 100 110 140 200 260
Power derating [%/K]
[%/m]
40 °C < T
V
< 55 °C: 2%/K (not UL approved)
1000 m amsl < h
4000 m amsl: 5%/1000m
Weight m[kg] 3.5 3.5 5.0 5.0 7.5
1)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned
here and 2 minutes base load with 75% I
ratedx
2)
When operated under rated load, the controller can supply this power additionally.
*
Chopper frequency of the inverter (C0018)
Show/Hide Bookmarks

Table of Contents

Other manuals for Lenze 9300