Installation
4-1
BA9300POS EN 2.3
4 Installation
4.1 Mechanical installation
4.1.1 Important notes
Use the controllers only as built-in devices!
If the cooling air contains pollutants (dust, fluff, grease, aggressive gases):
Take suitable preventive measures , e.g. separate air duct, installation of filters, regular
cleaning, etc.
Observefreespace!
You can install several controllers next to each other without free space in a control cabinet.
Ensure unimpeded ventilation of cooling air and outlet of exhaust air!
Allow a free space of 100 mm at the top and at the bottom.
Do not exceed the ambient temperature permissible during operation. (
^
3-2)
With continuous oscillations or vibrations:
Check whether shock absorbers are necessary.
Possible mounting positions
Vertically on the control cabinet back panel with mains connections at the top:
With enclosed fixing rails or fixing brackets. (
^
4-2)
Thermally separated with external heat sink
Punching
(
^
4-3)
Cold Plate technique” (
^
4-6)